Client LoginContact UsShopping Cart  
HOME
Toll Free: (800) 253-1230
Intl: (978) 461-2100
Fax: (978) 461-4295
QuadTech
 

Medical Systems

Software

Hipot Testers

LCR Meters

Megohmmeters

Milliohmmeters

Cable Testers

Ground Bond Testers

Accessories

Refurbished Equipment

Productos de QuadTech




Hipot Testers and Electrical Safety Testers

 

A hipot tester (hi pot tester or hy-pot tester) and instruments for Dielectric Withstand tests are used for performing either a series of or a specific electrical safety test on electrical components and products to ensure they meet operator safety requirements as well as comply with UL, CSA, IEC, and other standard certifying bodies. A high grade hipot medical safety analyzer must be able to perform high precision hi-pot testing and have reporting capabilities to indicate tested equipment falls within required specification.

Watch a QuadTech Sentry Hipot Tester used in an application.

 Hipot Testers and Electrical Safety Analyzer - performs hipot testing, insulation resistance tests and ground bond tests.  CaptivATE Automation Software is available.

Specialty Hipot Testers - used to perform high-voltage AC Hipot, ACDC Hipot and DC Hipot testing as well as insulation resistance testing and ground bond tests

Multi-Purpose Hipot Testers - performs insulation resistance testing, ground continuity and they have a broader testing range for AC Hipot, ACDC Hipot and DC Hipot tests.  CaptivATE Automation software is availble.

Basic Hipot Testers - economical, easy-to-use Hipot testers that perform simple AC Hipot, ACDC Hipot and DC Hipot tests

The medical safety analyzer and hipot testers shown in the tables below represent some of the highest quality electrical safety test units available.

Hipot Testers and Electrical Safety Analyzers

 

  

Guardian 6100 Plus
Hipot Tester and Medical Safety Analyzer*
Guardian 6000 Plus
Hipot Tester*
Hybrid 2000
Hipot Tester*
Other Capabilities Insulation Resistance and Simultaneous Ground Continuity (Ground Bond) and Hi-pot Testing
KEY FEATURES      
AC Hipot

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect; Filter
20A LC Scanner:
Earth, Enclosure, Patient, Pat. Aux
Functional Run:
(V), (A) or (VA) 

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect;
Filter

0.05 – 5kV
0.001 – 30mA
IReal , ITotal
HI/LO limits
Arc detect
DC Hipot 0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter

0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter 

0.05 – 6kV
0.0001 – 10mA
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50GW
HI/LO limits
0.05-1kVDC
100k-50GW
HI/LO limits
0.05 – 5kV
1MW – 50GW
Ground Continuity (Ground Bond)

GB: 1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA 

GB:1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA

DCR:
50m
Ω – 100mΩ
Other: OSC, PA

* CaptivATE Automation Software available

Top

MULTI-PURPOSE HIPOT TESTERS

 

Guardian 1010
Hipot Tester*

Guardian 1030
Hipot Tester*
Guardian 1030S
Hipot Tester*
Guardian 1050
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing
KEY FEATURES        
AC Hipot

0.05-5.0kVAC0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect  

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect  

 
DC Hipot  

 0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect

0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect  

 
Insulation Resistance (IR)   0.05-1kVDC
0.1M-50GW
HI/LO limits

0.05-1kVDC
0.1M-50GW
HI/LO limits

 
Ground Continuity (Ground Bond)

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GB: 3-45A AC
0.1m
Ω- 510mW
1.0-8.0V AC 

* CaptivATE Automation Software available

 Top

SPECIALTY HIPOT TESTERS

 

Guardian 500VA Hipot Tester
Guardian 10KVAC Hipot Tester Guardian 12KVDC Hipot Tester Guardian 20KVDC Hipot Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing.
KEY FEATURES        
AC Hipot

0.05-5.0kVAC
0.001-100mAAC
0.0001-20mADC
HI/LO limits
Arc detect

0.1 -10.0kVAC
0.001-20mAAC
HI/LO limits
Arc detect

 

 
DC Hipot 0.05-6.0kVDC
0.0001-20mADC
HI/LO limits
Arc detect

 

0.1-12.0kVDC
0.0001-10mADC
HI/LO limits
Arc detect

0.1-20.0kVDC
0.0001-5mADC
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50GW
HI/LO limits
 

0.1-1kVDC
100k-50GW
HI/LO limits

0.1-1kVDC
100k-50GW
HI/LO limits
Ground Continuity
(Ground Bond)

Other: PA

Other: PA

Other: PA

  Other: PA

   Top

BASIC HIPOT TESTERS

 

Sentry 10 Plus
Hipot Tester
Sentry 20 Plus
Hipot Tester
Sentry 30 Plus
Hipot Tester
Sentry 50 Plus
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Groundbond) Testing
KEY FEATURES        
AC Hipot

0.05-5.0kVAC
1 mA-20mAAC
HI/LO limits
Arc detect  

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect  

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect  

 
DC Hipot  

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect  

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect  

 
Insulation Resistance (IR)    

0.5-1kVDC
0.1M-50GW  

 
Ground Continuity
(Ground Bond)

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA  

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA  

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA  

GB: 3-30A AC
0.1m
Ω- 510mΩ
1.0-8.0V AC  

Top

View our complete Hipot Tester and Electrical Safety Test Selection Guide
Read some of QuadTech's application notes highlighting
Hipot Testers!

 

Home   Customer Support   Contact Us   Privacy Policy   Shopping Cart   Site Map
Copyright © 2007 QuadTech. All rights reserved. Site designed and maintained by Sagebridge Solutions