Electrical Test Meters for Ground Bond Testers

A ground bond test or ground bond testing is usually the first test performed to meet the standards of an electrical safety test specification. Electrical test meters, such as dielectric testers, are instruments that are utilized to perform ground bond tests to examine insulating materials by applying a higher voltage than a component is usually rated over a specified period of time.

The result of ground bond testers is to measure resistance value (R). If this value is lower than the limit set by the international standards specification, the component passes the ground bond test. The electrical test meters below represent QuadTech's top of the line ground bond testers and electrical safety test equipment – these electrical test meters are instruments used for measuring high current ground bond up to 45A.

Use the "quick select" chart below to help you find the right ground bond tester to satisfy your electrical safety testing needs. **Note - All units come fully calibrated at time of purchase** 

GROUND BOND TESTERS

 

  

Guardian 1050
Ground Bond Tester
Sentry 50 Plus
Ground Bond Tester
Guardian 6100 Plus
Hipot Tester and Medical Safety Analyzer*
Guardian 6000 Plus
Hipot Tester*
Other Capabilities Insulation Resistance testing and Ground Continuity or Ground Bond testing, electrical test meters 
KEY FEATURES      
Test Current

3A – 45A

3A – 30A

1A – 60A*
RS-232 Interface Optional

No

Standard
IEEE-488 Interface Optional No Optional
Printer Interface Optional No Optional
Hipot Connection Yes Yes Hipot Contained
Resolution 0.01A 0.01A 0.01A
Basic Accuracy 1% of setting + 0.3A 1% of setting + 0.3A 1% of setting + 0.3A
Voltage 1.0 – 8V AC, 0.01V/step 1.0 – 8V AC, 0.01V/step 6.0 – 15V AC, 0.01V/step
Resistance 0.1mΩ – 510.0mΩ 0.1mΩ – 510.0mΩ 0.1mΩ – 510.0mΩ
Accuracy 1% of reading +5 counts 1% of reading +5 counts 1% of reading +3 counts
Frequency 50/60 50/60 50/60
Test Setup Storage 99 locations/99 Steps 99 locations/99 Steps 100 locations/50 Step
Remote Control 9-pin PLC
S/R/UT/I/P/F
9-pin PLC
S/R/UT/I/P/F
9-pin PLC
Kelvin Test Leads Standard Standard Standard
Hipot Compatibility G1000 Series Sentry Plus Series Hipot Contained

* CaptivATE Automation Software available