EST Scanner Functions
- Programmable hipot output voltage to 5kV AC and 6kV DC
- Trip current programmable to 30mA AC and 10mA DC
- Insulation resistance to 50GΩ / 5KV DC
- DCR 10mΩ ~ 100kΩ
- Built-in 8 channel scanner
- Storage of 20 tests setups with 50 steps per setup
Key Features
- Open/Short check (OSC) function to ensure of DUT connection
- SUB-STEP function
- GFI Human protection - shutdown if current imbalance >0.5mA
- DWX Series - Impulse Winding Tester compatable
- Flashover detection
- Key Lock function
- RS232 Interface (standard)
- GPIB & Handler (optional)
- Friendly interface
- CE Mark
Applications
The Hybrid 2000 is a comprehensive tester designed for wound component safety and design verification testing requirements.
- Motor, Fan
- Electric Heater Tube
- Transformer
- Switch, Wire
- Camera Micro Motor, Coil
Information
Chroma Newsletter
Get our Newsletter: Click the link below to register.
Follow Us
Hybrid 2000 - Wound Component EST Scanner
The Hybrid 2000 Wound Component Scanner is a production safety tester designed for test requirements of three-phase motors, double-wound transformers and heater related wound components. Quality verification test items for wound components consist of AC/DC Hipot (dielectric withstanding), Insulation Resistance (IR), and Impulse Winding tests. We have integrated these tests into one unit.
Hipot, IR, and Impulse Winding Test
 |
Hybrid 2000 AC/DC Hipot, IR, DCR
CE Mark |
 |
The Hybrid 2000 is designed to directly connect to a DWX Series Impulse Winding Tester and use the 8-Channel scanning capabilities to reach multiple points in one test instead of switching test points manually.
See Specs |
Ordering information
Hybrid 2000: Wound Component EST Scanner
A190345: High voltage cable for Impulse Winding Tester connection
A190346: RS-232 cable for Impulse Winding Tester connection
A190347: GPIB, Handler & Temperature interface |
A190348: RS-232 Interface
A190351: 8ch-16ch HV box
A190352: Wound Componenet pneumantic scan box
A190354: Dual switch fixture for A190352
A190702: 40kV HV Test probe |
Specifications
Hybrid 2000 |
Mode |
AC/DC/IR/
DCR -8CH/ IWT |
Impulse Winding Test
(Layer Short, IWT) |
External option |
Channel Programming |
H/L/X in 8CHs |
Withstanding Voltage Test |
Output Voltage |
AC: 0.05~5KV / DC: 0.05~6KV |
Load Regulation |
±(1% setting + 0.1%full Scale) |
Voltage Regulation |
2V |
Voltage Accuracy |
1% setting + 0.1% full Scale |
Cutoff Current |
AC: 30mA / DC: 10mA |
Current Resolution |
AC: 1µA / DC: 0.1µA |
Current Accuracy |
1% of reading + 0.5% of range (1% of reading + 5% of total current)
|
Current Frequency |
50Hz / 60Hz |
Test Time |
0.1 ~ 999 sec , continue |
Test / Ramp / Fall / Dwell Time |
0.3 ~ 999 sec., continue / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off |
Wave Form |
Sine wave |
Insulation Resistance Test |
Output Voltage |
DC : 0.05 ~ 5kV |
Voltage Resolution |
2V |
Voltage Accuracy |
1% of setting + 0.1% of full range |
IR Range |
1MΩ ~ 50GΩ |
Resistance Resolution |
0.1MΩ |
Resistance Accuracy |
≧1000V |
0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range) |
500V~1000V |
0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range) |
≦500V |
0.1MΩ ~ 1GΩ : ± 3% of reading + (0.2*500/Vs)% of full scale |
DC Resistance Measurement |
Test Signal |
<DC 10V. < DC 100mA |
Measurement mode |
2 terminals (2W) / 4 terminals(4W) measurement selectable |
Measurement Accuracy
(2W/ 4W) |
1Ω (4W only) |
±(0.5% of reading + 0.5% of range) |
10kΩ |
± (2% of reading + 0.5% of range) / ± (0.5% of reading + 0.05% of range) |
100kΩ |
1kΩ |
10kΩ |
100kΩ |
Flashover Detection |
Setting Mode |
Programmable setting |
Detection Current |
AC : 1mA ~ 15mA, DC : 1mA ~ 10mA |
Secure Protection Function |
Fast Output Cut-off |
0.4ms after NG happen |
Ground Fault Interrupt
|
0.5mA ±0.25mA AC, ON/OFF |
Panel Operation Lock |
Present password |
Interlock |
YES |
GO/NG Judgment Window |
Indication, Alarm
|
GO : Short sound, Green LED; NG : Long sound, Red LED |
Data Hold |
Least tests data memories |
Memory Storage |
50 instrument setups with up to 20 test steps |
Interface |
RS232*1 (Standard), RS232*1 or GPIB & Handler & Temperature interface (Optional). |
General |
Operation Environment |
Temperature : 0°C~45°C, Humidity : 15% to 95% R.H@≦40°C |
Power Consumption |
500VA |
Power Requirements |
90~132Vac or 198~264Vac, 47~66Hz |
Weight |
Approx. 20KG |
Certifications |
 |
|
*All specifications subject to change without notice.